11.1.2 Non-contiguous multi-site configuration
It is not necessary to give the different cells different numbers in the MMCs.
The following MMCs must be implemented:
Declare the same PARI on all the sites.
Same RANDOM registration number on all the sites.
Same RS registration number on all the sites.
Same MOBILE registration password on all the sites.
Broadcast of call setup requests must be configured to reach the sites with base stations
on NeXspan 50: MMC XSERVI
sub-object "Radio zones", field "Zone= . ."
sub-object "General", field "Addr-nat."= F4, 2nd byte=BF (All sites of all centers)
on NeXspan C/S/L: menu 1.8.1.2 or 1.9.1.2 "DECT Parameters"
parameter "search mobiles not registered"
Create a broadcast list A with all the sites where the DECT is present.
11.2 Declaring the radio zones on NeXspan 50 / NeXspan 500
MMC XSERVI
SERVICES MANAGEMENT
Obj.=Dept. Action=Display
Sub-Object=GENERAL
----------------------------- SERVICE ACCESS --------------------------
Template CCU=2.
KEY: Address-nature = F4 2nd byte (comp_ovflw) = FE
----------------------------- SERVICE DATA --------------------------
CCU selection mode = FIXED
Number of CCUs = 1
Sites and Clusters in Hex from 0 to FEH
1 : Site=BF CCU = ..
2 : Site=.. Cluster = ..
3 : Site=.. Cluster = ..
4 : Site=.. Cluster = ..
5 : Site=.. Cluster = ..
6 : Site=.. Cluster = ..
7 : Site=.. Cluster = ..
8 : Site=.. Cluster = ..
Subscr. number = ........
---------------------------------------------------------------------------
Report=O.K.