95
Ratings and fuses
I
II
III
IV
Type
ACQ580
Input
rating
Output ratings Heat
dissipation
Air flow Frame
size
Nominal use
-01-
I
1N
I
N
P
N
A A kW W
m
3
/h
3-phase U
N
= 400 V (380…415 V)
088A-4 88 88 45 1240 139 R5
106A-4 106 106 55 1510 139 R5
3AXD00000586715.xls H
Type
ACQ580
Input
rating
Output ratings Heat
dissipation
Air flow Frame
size
Nominal use Heavy duty use
-01-
I
1N
I
Ld
P
Ld
I
Hd
P
Hd
A A hp A hp W
ft
3
/min
3-phase U
N
= 480 V (440…480 V)
088A-4 77 77 60 65 50 1240 82 R5
106A-4 96 96 75 77 60 1510 82 R5
3AXD00000586715.xls H
Type
ACQ580
-01-
gG
I
N
I
2
t Voltage rating ABB type
Type
IEC 60269
A A
2
s V
3-phase U
N
= 400/480 V (380…415 V, 440…480 V)
088A-4 100 65000 500 OFAF000H100 000
106A-4 125 103000 500 OFAF00H125 00
3AXD00000586715.xls H
Type
ACQ580
-01-
uR or aR
I
N
I
2
t Voltage rating Bussmann type
Type
IEC 60269
A A
2
s V
3-phase U
N
= 400/480 V (380…415 V, 440…480 V)
088A-4 160 16000 690 170M1569 000
106A-4 200 15000 690 170M3815 1
3AXD00000586715.xls H
3AXD50000035755 Rev A