ACS 300 User’s Manual 59
Chapter 7 - Drive Parameters
Figure 7-4 Example of critical frequencies setting.
The following is an alternative way to enter the LOW and
HIGH settings for critical frequency:
Run the drive with external reference.
Using the analog input, set the frequency to the critical
frequency LOW value.
Go to parameter CRIT f1L on Page 2.
Press and hold the key for three seconds.
The ACS 300 will respond by updating the frequency set-
ting to the current value. The CRIT f1L is now set.
Increase the analog input reference so that the output fre-
quency is just above the critical frequency span.
Go to parameter CRIT f1H on Page 2.
f
motor
[Hz]
f
REF
[Hz]
f1L
18
f1H
23
f2L
46
f2H
52
52
46
23
18