74 ACS 300 User’s Manual
Chapter 8 - Fault Tracing
Figure 8-1 Examples of fault indications in the fault memory.
Fault Tracing Table 8-1 shows the displayed fault text (in the FAULT MEM-
ORY); the probable cause of the fault; and advice for cor-
recting the fault.
= Press once to reset fault.
= Switch power off to reset fault.
Fault Memory can be erased by pressing simultaneously
button and - button while reviewing Fault Memory.
Erasing will clear all three fault records.
F1 OVERVOLTAGE F2 UNIT FAULT 12