Drive module of frame size R7 with bottom exit
13
Layout of the installation
This photo shows the final installation with component placing dimensions in
millimetres and (inches).
Base plate
570 (22.44)
837 (32.95)
910 (35.83)
1080 (42.52)
1420 (55.91)
220 (8.66)
320 (12.60)
455 (17.91)
1520 (59.84) to the fastening points
The drive module is placed 30 mm (1.18 in.) from
the right-hand side panel. Fastening point distances
from the bottom of the back mounting plate are
shown. The distance of the back mounting plate
from the base plate of the enclosure is 50 mm
(1.97 in.)
Contactor
EMC filter *
RDCU
Switch fuse
635 (25.00)
970 (38.19)
EMC compatible*
air filter
SK 3326.267
Cutting in the door:
292 × 292
(11.50 × 11.50)
4
3
0
95 (3.74)
from the
door edge
1387 (54.61)
2
3
5
(
9
.
2
5
)
(
1
6
.
9
3
)
Note: A mirrored layout is advantageous for
servicing the drive module.
EMC screen *
Air baffle
Cutting in the door:
115 × 240
(4.53 × 9.45)
PE
C-rail 600 mm
Side mounting plate
TS 8614.240
1100 mm × 300 m m
Punched section
TS 8612.160
(600 mm)
Punched section
TS 8612.160
* required in first environment installations only
Support rail PS 4944.000
C-rail 390 mm
C-rail 600 mm
user’s cabling
EMC compatible*
fan-and-air-filter unit
SK 3326.607
Auxiliary voltage
transformer
Gasket strip
64331116