EasyManua.ls Logo

ABB ACS800-04M - Swapping the Pedestal Output Busbars to the Left-Hand Side

ABB ACS800-04M
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical installation of non-pre-assembled units (ACS800-04M)
106
Swapping the pedestal output busbars to the left-hand side
Disconnect the horizontal pedestal busbars from the busbars that connect them
to the adapter.
Push the horizontal busbars to the left.
Reconnect the horizontal busbars to the adapter connecting busbars.
Note:
When the pedestal busbars are swapped to the left:
vertical output busbars cannot be installed.
the unit cannot be mounted on a wall with the wall mounting bracket included in
the delivery.
ensure that the required clearance between the cabinet base or floor and the
cable lugs or busbars used in the cabling is at least 13 mm (1/2 in.). Otherwise,
insulating material must be used below the drive module.
fasten the left-hand side PE terminal in frame size R7. In frame size R8, fasten
the PE busbar as follows.
Left
Right
Front (the profiled side)
PE busbar
Fastening of the PE busbar in frame size R8

Table of Contents

Other manuals for ABB ACS800-04M