EasyManua.ls Logo

ABB DCS 600 - Description of I;O Signals

ABB DCS 600
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
II F 2-10
Description of I/O signals SDCS-CON-2
Mechanical system installed in the basic unit
Terminals
Screw-type terminals for finely stranded wires up to max. 2.5 mm
2
cross-sectional area
Functionality
ð 1 tacho input
Resolution: 12 bit + sign; differential input; common-mode range ±20 V
3 ranges from 8...30...90...270 V- with n
max
ð 4 analogue inputs
Range -10...0...+10 V, 4...20 mA, 0...20 mA
All as differential inputs; R
E
= 200 kΩ; time constant of smoothing
capacitor 2 ms
Input 1: Resolution: 12 bit + sign.; common-mode range ±20 V
Inputs 2, 3, 4: Resolution: 11 bit + sign; common-mode range ±40 V
ï 2 outputs
+10 V, -10 V, I
A
5 mA each; sustained-short-circuit-proof
for reference potentiometer voltage supply
ï 1 analogue output
bipolar current feedback - from the power section; decoupled
IdN ⇒ ±3 V; I
A
5 mA, short-circuit-proof
ï 2 analogue outputs
Range -10...0...+10 V; I
A
5 mA
Output signal and scaling can be selected by means of the software
Resolution: 11 bit + sign
ð 1 pulse generator input
Voltage supply for 5 V/12 V/24 V pulse generators (sustained-short-
circuit-proof)
Output current with 5 V: I
A
0.25 A
12 V: I
A
0.2 A
24 V: I
A
0.2 A
Input range: 12 V/24 V: asymmetrical and differential
5 V: differential
Pulse generator as 13 mA current source: differential
Line termination (impedance 120), if selected
max. input frequency 300 kHz
ð 8 digital inputs
The functions can be selected by means of the software
Input voltage: 0...8 V "0 signal", 16...60 V "1 signal"
Time constant of smoothing capacitor: 10 ms
R
E
= 15 k
The signal refers to the unit casing potential
Auxiliary voltage for digital inputs: +48 V-, 50 mA, sustained-short-
circuit-proof
ï 7+1 digital outputs
The function can be selected by means of the software
7 outputs: relay driver with free-wheel diode, total current limitation
160 mA, short-circuit-proof
1 relay output - on power pack board SDCS-POW-1 (N.O. contact
element: AC: 250 V/ 3 A / DC: 24 V/ 3 A or 115/230 V/ 0.3 A)
protected by VDR component.
Description of I/O signals SDCS-IOB-2x & SDCS-IOB-3
Mechanical system always external, outside the basic unit
Terminals
Screw-clamp terminals for finely stranded wires up to max. 2.5 mm
2
cross-sectional area
Functionality of SDCS-IOB-3
ð 1 tacho input
Resolution: 12 bit + sign; differential input; common-mode range ±20 V
Range 8 V- with n
max
; if higher tacho voltages are in use the tacho
adaptation board PS 5311 is needed.
ð 4 analogue inputs
All as differential inputs; time constant of smoothing capacitor 2 ms
Input 1: Range -10 V/-20 mA...0...+10 V/+20 mA; 4... 20 mA unipolar;
R
E
= 200 k/ 500/ 500; Resolution: 12 bit + sign; common-mode
range ±20 V
Inputs 2+3: Range as with input 1, in addition -1 V...0...+1 V
R
E
= 200 k/ 500/ 500/ 20k; Resolution: 11 bit + sign; common-
mode range with -1 V...0...+1 V range ±10 V, otherwise ±40 V
Input 4: Range as with input 1
R
E
= 200 k/ 500/ 500; Resolution: 11 bit + sign; common-mode
range ±40 V
ð Error current detection in combination with analogue input 4
(sum of phase currents 0)
ï 2 outputs
+10 V, -10 V, I
A
5 mA each; sustained-short-circuit-proof
for reference potentiometer voltage supply
ï 1 analogue output
Bipolar current feedback - from the power section; decoupled
IdN ⇒ ±3 V (at gain = 1); I
A
5 mA, U
Amax
= 10 V, gain can be adjusted
by means of a potentiometer between 0.5 and 5, short-circuit-proof
ï 2 analogue outputs
Range -10...0...+10 V; I
A
5 mA; short-circuit-proof
Output signal and scaling can be selected by means of the software
Resolution: 11 bit + sign
ï Current source for PT 100 or PTC element evaluation
I
A
= 5 mA / 1.5 mA
ð 1 pulse generator input
Voltage supply, output current, input range: as with IOB1
Inputs electrically isolated from 0 V (casing earth) by means of optocou-
pler and voltage source.
Functionality of SDCS-IOB-2x
3 different designs available:
m SDCS-IOB-21 inputs for 24...48 V-; R
E
= 4.7 k
m SDCS-IOB-22 inputs for 115 V AC; R
E
= 22 k
m SDCS-IOB-23 inputs for 230 V AC; R
E
= 47 k
Terminals
Screw-clamp terminals up to max. 4 mm
2
cross-sectional area
ð 8 digital inputs
The functions can be selected by means of the software
The signal status is indicated by an LED
all isolated by means of optocouplers
Input voltage: IOB-21:0...8 V "0 signal", 18...60 V "1 sig."
IOB-22:0...20 V "0 signal", 60...130 V "1 sig."
IOB-23:0...40 V "0 signal", 90...250 V "1 sig."
Filter time constant: 10 ms (channels 1...6), 2 ms (channels 7+8)
Auxiliary voltage for digital inputs: +48 V-, 50 mA, sustained- short-
circuit-proof; referenced to the unit casing potential
ï 8 digital outputs
The functions can be selected by means of the software
The signal status is indicated by an LED
6 of them potential-isolated by relay (N.O. contact element: AC: 250 V/
3 A / DC: 24 V/ 3 A or 115/230 V/ 0.3 A) , protected by VDR
component.
2 of them potential-isolated by optocoupler, protected by Zener diode
(open collector) 24 V DC external, I
A
50 mA each.

Table of Contents