EasyManua.ls Logo

ABB DCS880 - Safety Instructions; Installation and maintenance work

ABB DCS880
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Table of contents
3ADW000488R0101 DCS880 Service manual e a
Remove faulty thyristor modules .................................................................................................................... 28
Install new thyristor modules .......................................................................................................................... 33
Remove faulty SDCS-BAB-F0x ...................................................................................................................... 35
Install new SDCS-BAB-F0x ............................................................................................................................ 36
Thyristor module and SDCS-BAB-F0x location in DCS880-S01 (2-Q) units.................................................. 37
Thyristor module and SDCS-BAB-F0x location in DCS880-S02 (4-Q) units.................................................. 39
Thyristor module terminals and SDCS-BAB-F0x ............................................................................................ 40
Exchange thyristors size H6 41
Installation of thyristor modules in converters size H6 (900 … 2000 A) ............................................................. 41
Required tools ................................................................................................................................................. 41
Find faulty thyristor modules ........................................................................................................................... 42
Remove faulty thyristor ................................................................................................................................... 43
Install new thyristor ......................................................................................................................................... 44
Location of thyristors in frame H6 (4-Q bridge) .............................................................................................. 45
Location of thyristors in frame H6 (2-Q bridge) .............................................................................................. 45
Location of branch fuses frame H6 ................................................................................................................. 46
Exchange thyristors size H7 47
Installation of thyristor modules in converters size H7 (1900 … 3000 A) ........................................................... 47
Required tools ................................................................................................................................................. 47
Bidirectional-Controlled-Thyristors (BCTs) ..................................................................................................... 48
Find faulty thyristor modules ........................................................................................................................... 49
Remove faulty thyristor ................................................................................................................................... 50
Install new thyristor ......................................................................................................................................... 53
Location of thyristors in frame H7 (4-Q bridge with single thyristors) ............................................................. 55
Location of thyristors in frame H7 (4-Q bridge with BCTs) ............................................................................. 56
Location of thyristors in frame H7 (2-Q bridge with single thyristors) ............................................................. 57
Location of branch fuses frame H7 ................................................................................................................. 58
Exchange thyristors size H8 59
Installation of thyristor modules in converters size H8 (2500 … 5200 A) ........................................................... 59
Required tools ................................................................................................................................................. 59
Find faulty thyristor modules ........................................................................................................................... 60
Remove faulty thyristor ................................................................................................................................... 62
Install new thyristor ......................................................................................................................................... 64
Location of thyristors in frame H8 (4-Q bridge) .............................................................................................. 66
Location of thyristors in frame H8 (2-Q bridge) .............................................................................................. 66
Location of branch fuses frame H8 (busbars on the right) ............................................................................. 67
Location of branch fuses frame H8 (busbars on the left)................................................................................ 68
Exchange the control unit (SDCS-CON-H01) 69
General ............................................................................................................................................................... 69
Required Tools ................................................................................................................................................ 69
Overview of control unit exchange .................................................................................................................. 69
Safe Torque Off (STO) 73
Contents of this chapter ...................................................................................................................................... 73
Description .......................................................................................................................................................... 73
Operation principle .............................................................................................................................................. 73
Flow chart ........................................................................................................................................................... 74
STO revalidation test .......................................................................................................................................... 76
Test procedure ................................................................................................................................................ 76
Evaluation of the graph and observations ...................................................................................................... 78
Repetitive function test (fault shutdown path) ..................................................................................................... 80
Fault shutdown path ....................................................................................................................................... 80
Test procedure ................................................................................................................................................ 80
Evaluation of the graph and observations ...................................................................................................... 82
Acceptance test .................................................................................................................................................. 84

Table of Contents

Other manuals for ABB DCS880

Related product manuals