Start-up 37
27 FBA PAR
REFRESH
Validates any changed adapter module
configuration parameter settings. After
refreshing, the value reverts automatically to
0 = Done.
Note: This parameter cannot be changed
while the drive is running.
0 = Done
ACS355/ACSM1:
FBA PAR
REFRESH
ACS850/ACS880/
ACS580:
FBA par refresh
0 = Done Refreshing done
1 =
Refresh/Configure
Refreshing
28 PAR TABLE VER Read-only. Displays the parameter table
revision of the fieldbus adapter module
mapping file stored in the memory of the
drive.
N/A
ACS355:
FILE CPI FW REV
ACSM1:
PAR TABLE VER
ACS850/ACS880/
ACS580:
Par table ver
Parameter table revision
29 DRIVE TYPE
CODE
Read-only. Displays the drive type code of
the fieldbus adapter module mapping file
stored in the memory of the drive.
N/A
ACS355:
FILE CONFIG ID
ACSM1:
DRIVE TYPE
CODE
ACS850/ACS880/
ACS580:
Drive type code
Drive type code of the fieldbus adapter
module mapping file
No. Name/Value Description Default