InformationAction
Make sure that the cover is tightly
sealed.
Applicable to motors axes 3, 4, 5 and 6!
Refit the cover in the back of the armhouse
with its attachment screws and washers.
WARNING
The cover on the armhouse must be fitted when
the robot is running. It is a vital part for the
stability of the robot.
22
A
B
xx0800000389
Parts:
A: Cover
B: Attachment screws M6x25,
quality 8.8-A2F (8 pcs)
Tightening torque:
14 Nm
Pendulum Calibration is described in
Operating manual - Calibration Pendu-
lum, enclosed with the calibration
tools.
Recalibrate the robot.23
Axis Calibration is described in Calib-
rating with Axis Calibration method on
page 412.
General calibration information is in-
cluded in section Calibration on
page 397.
DANGER
Make sure all safety requirements are met
when performing the first test run. See Test run
after installation, maintenance, or repair on
page 113.
24