Additional stops
The additional stops are fitted as shown in the figure.
A
B
C
D, E
xx0800000273
Movable mechanical stop. Limited to:
-126° (IRB 2600-20/1.65 type C, IRB 2600-12/1.65 type C)
-129° (IRB 2600-20/1.65, IRB 2600-12/1.65, IRB 2600-12/1.85, IRB 2600ID-
15/1.85, IRB 2600ID-8/2.0)
A
Movable mechanical stop. Limited to:
+13.5° (IRB 2600-20/1.65 type C, IRB 2600-12/1.65 type C)
+16.5° (IRB 2600-20/1.65, IRB 2600-12/1.65, IRB 2600-12/1.85, IRB 2600ID-
15/1.85, IRB 2600ID-8/2.0)
B
Movable mechanical stop. Limited to:
-13.5° (IRB 2600-20/1.65 type C, IRB 2600-12/1.65 type C)
-16.5° (IRB 2600-20/1.65, IRB 2600-12/1.65, IRB 2600-12/1.85, IRB 2600ID-
15/1.85, IRB 2600ID-8/2.0)
C
Attachment screwsD
WashersE
Continues on next page
Product manual - IRB 2600 89
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
2 Installation and commissioning
2.4.2 Mechanically restricting the working range of axis 1
Continued

Table of Contents