Device designs   
12 - EN  FEX300, FEX500  SM/FEX300/FEX500/FM/CSA-EN 
3.4.2  Name plate for model with integral mount design (single-compartment housing) 
 
Fig. 2 
„A“ Name plate 
1  Model number (for more detailed information about 
the technical design, refer to the data sheet or the 
order confirmation) 
2 Order no. 
3  Meter size and nominal pressure rating 
4  Tmed = maximum permissible fluid temperature 
  Tamb = maximum permissible ambient temperature 
5  Protection type according to EN 60529 
6  Calibration value Qmax DN 
7  Communications protocol of transmitter 
8 Software version 
9 CE mark 
10 Client-specific TAG number (if specified) 
11 Material: Flange/lining/electrode 
12 Excitation frequency of sensor coils 
13 Supplementary information: EE = grounding 
electrodes, TFE = partial filling electrode  
14 Calibration value Ss (span) 
  Calibration value Sz (zero point) 
  Accuracy to which the unit was calibrated 
(e.g., 0.4% of rate) 
15
Supply voltage 
16 Year of manufacture 
17 Label indicating whether the unit is subject to the 
Pressure Equipment Directive (PED). 
  Information on the relevant fluid group. 
  Fluid group 1 = hazardous fluids, liquid, gaseous. 
(Pressure Equipment Directive = PED). 
  If the pressure equipment is not subject to the 
Pressure Equipment Directive 2014/68/EU, it is 
classified in accordance with SEP (= sound 
engineering practice) as per Art. 3 Para. 3 of the 
PED. 
  If no such information is present, it means that the 
device does not claim to comply with the 
requirements of the Pressure Equipment Directive 
2014/68/EU. Water supplies and connected 
equipment accessories are classed as an exception 
in accordance with guideline 1/16 of Art. 1 Para. 3.2 
of the Pressure Equipment Directive. 
 
„B“ Ex mark according to FM and cFM (example)  „C“ Safety mark 
 
 
IMPORTANT (NOTE) 
Meters with 3A approval are labeled with an additional plate. 
 
 
G01333