Drive configuration
34
Table 8. The RETA-01 configuration parameters
Par.
no.
Parameter name Alternative settings Default
setting
1 MODULE TYPE (Read-only) ETHERNET
2 Comm rate (0) Auto-negotiate; (1) 100 Mbit/s,
full duplex; (2) 100 Mbit/s, half
duplex; (3) 10 Mbit/s, full duplex;
(4) 10 Mbit/s, half duplex
(0) Auto-negotiate
3 DHCP (0) DHCP disabled; (1) DHCP
enabled
(1) DHCP enabled
4 IP address 1 0…255 0
5 IP address 2 0…255 0
6 IP address 3 0…255 0
7 IP address 4 0…255 0
8 Subnet mask 1 0…255 0
9 Subnet mask 2 0…255 0
10 Subnet mask 3 0…255 0
11 Subnet mask 4 0…255 0
12 GW address 1 0…255 0
13 GW address 2 0…255 0
14 GW address 3 0…255 0
15 GW address 4 0…255 (0) 0
16 Protocol (0) Modbus/TCP;
(1) Ethernet/IP AC/DC
communication profile;
(2) Ethernet/IP ABB Drives
communication profile
(0) Modbus/TCP
17 Modbus timeout 0…65535 0
18 Stop function (0) Ramp stop; (1) Coast stop (0) Ramp stop
19 Output 1 0…65535 0
20 Output 2 0…65535 0

Table of Contents