Communication
88
0x16 Parameter address
impermissible
Illegal value or value that is not
supported for the attribute, number of
elements, parameter number or sub-
index, or a combination
0x17 Illegal format Write request: Illegal format or format of
parameter data that is not supported
0x18 Number of values inconsistent Write request: Number of values of
parameter data does not match number
of elements at the parameter address
0x19 DO nonexistent Request to DO, which does not exist
0x65…
0xFF
Manufacturer-specific –
0x65 Vendor-specific error Vendor-specific error
0x66 Request not supported Request not supported
0x67 Communication error Request cannot be completed because
of communication error
0x6F Time-out error Request aborted due to time-out
0x78 PZD map failure Parameter cannot be mapped to PZD
(size mismatch or non-existent)
0x79 PZD memory failure Parameter cannot be mapped to PZD
(out of memory)
0x7A Multiple PZD map Parameter cannot be mapped to PZD
(multiple PZD write)
0x8C Set torque mode error Cannot change mode to TORQUE
(frequency is used)
0x90 Illegal Request ID The request ID of the response is illegal