EasyManua.ls Logo

ABB RETA-02 - Page 96

ABB RETA-02
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication
96
972 V/P R/W Unsigned16 Software reset
Value Description
0 No action
1 Power-cycle PROFINET
IO module
The parameter must do a zero-to-one
transition and the motor must be
stopped.
975 P R Array [8]
Unsigned16
Drive Object identification
Subindex Contents
0 Manufacturer
1DO type
2 Version
3 Firmware date (year)
4 Firmware date
(day/month)
5 PROFIdrive DO type
class (0x0001-Axis)
6 PROFIdrive DO sub-
class 1(Application class
7 Drive Object ID (0x0001)
976 V/P R/W Unsigned16 Load device parameter set
Value Description
0 No action
1 Changes parameters to
factory settings
The parameter must do a zero-to-one
transition and the motor must be
Para-
meter
Mode
***
R/W
*
Data type Description

Table of Contents

Related product manuals