EasyManua.ls Logo

ABB Terra 94 - Safety Instructions During Cleaning or Maintenance; Safety Instructions for Earthing; Signs on the EVSE

ABB Terra 94
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.6 Safety instructions during cleaning or maintenance
Preliminary requirements
Keep unauthorized personnel at a safe distance during cleaning or maintenance.
If for cleaning or maintenance it is necessary to remove safety devices, immediately
install the safety devices after the work.
Put on the correct personal protective equipment. Refer to section
3.4
.
3.7 Safety instructions for earthing
Make sure that the EVSE is connected to an earthed, metal, permanent electrical
system. Alternatively, install an equipment-earthing conductor with circuit conductors.
Connect this earthing conductor to an equipment-earthing terminal or lead on battery
charger.
Make sure that the connections to the EVSE comply with all applicable local rules.
3.8 Signs on the EVSE
Symbol Risk type
General risk
Hazardous voltage that gives risk of electrocution
Risk of pinching or crushing of body parts
Rotating parts cat can cause a risk of entrapment
PE
Safety
20 BCM.S1101.0-EN | 001

Table of Contents