EasyManua.ls Logo

ABB Terra 94 - Measure the DC Voltage; Remove Condensation from the Cabinet

ABB Terra 94
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
• Voltage tester
Procedure
1. Measure the AC voltage between the terminals on the surge protection device switch:
•
R, S
and
T
to
N
•
R
to
S
•
R
to
T
•
S
to
T
Use the voltage tester.
Note: The surge protection device switch shows the indications
R, S, T
and
N
.
4.6.3 Measure the DC voltage
Preliminary requirements
1. • Only do this procedure if a
different procedure refers to
this procedure.
• Voltage tester
Procedure
1. Measure the DC voltage between the
output terminals:
• Power module group output 1- (A) to
power module group output 1+ (B)
• Power module group output 2- (C) to
power module group output 2+ (D)
• EV charge cable 1 output - (E) to EV
charge cable 1 output + (F)
• EV charge cable 2 output - (G) to EV
charge cable 2 output + (H)
Use the voltage tester.
4.7 Remove condensation from the cabinet
If the EVSE is off for more than two hours, condensation can occur.