8 - Maintenance
Routine maintenance
To preserve long term proper operation of the inverter, you are advised to
perform the routine maintenance operations listed in this chapter.
Maintenance operations shall be performed only by qualied personnel or ABB personnel
(under a servicing contract). The maintenance schedule may vary depending on the envi-
ronmental conditions of the installation.
Table: routine maintenance
Annual visual
inspections
Check that the inverter is operating properly, without any alarm signals
Ensure that all the safety labels and symbols are visible
Check the integrity of the cables, connectors and cable glands outside the
inverter
Check that the environmental conditions have not changed dramatically from
those on installation
• Check there are no obstacles (animals, insects, leaves or anything which
could reduce the heat exchanging capacity of the heat sink) at the top, at the
bottom and between the ns.
Annual operations
Check the tightening of the cable glands and AC connector cable gland.
Check the front cover is fixed
If there is no monitoring system, check the record of alarms and errors using
the indications given in the manual in order to check recent malfunction signals
Annual cleaning
Clean the equipment; in particular the heat sink (using compressed air)

Table of Contents

Other manuals for ABB UNO-DM-1.2-TL-PLUS-Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB UNO-DM-1.2-TL-PLUS-Q and is the answer not in the manual?

ABB UNO-DM-1.2-TL-PLUS-Q Specifications

General IconGeneral
BrandABB
ModelUNO-DM-1.2-TL-PLUS-Q
CategoryInverter
LanguageEnglish

Related product manuals