CAT 3 7Operation
7Operation
As the CAT 3 is integrated into the torch’s welding process, the operating steps
are performed after the respective torch has been put into operation.
8 Putting out of operation
Putting out of operation depends on the respective welding torch.
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life
and trouble-free operation. During such activities, observe the following:
NOTICE
The device may only be operated by qualified personnel (in Germany
see TRBS 1203).
Please also consult the operating instructions for the welding
components, such as the power source and compressed air line.
NOTICE
When putting the system out of operation, ensure that the procedures for
switching off each of the welding system components are observed.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
Switch off the power source.
Close the compressed air supply.
Close the gas supply.
Switch off the entire welding system.
Pull the mains plug at the robot welding power source.
DANGER
Electric shock
Dangerous voltage due to defective cables.
Check all live cables and connections for proper installation and
damage.
Replace any damaged, deformed or worn parts.