7: Operations, Administration & Maintenance
Transmitted and Received event notifications
OAM Local Error Symbol Period Event
A sequence of six integers corresponding to the respective fields in the most recently transmitted Errored Symbol Period
Event TLV in an Event Notification OAMPDU. This sequence is updated when a request service primitive is generated
within the OAM sublayer with an OAMPDU Code field value equal to the Event Notification code and Event TLV Type field
equal to the Errored Symbol Period Event value.
The first INTEGER represents the Event Time Stamp field.
The second INTEGER represents the Errored Symbol Window field.
The third INTEGER represents the Errored Symbol Threshold field.
The fourth INTEGER represents the Errored Symbols field.
The fifth INTEGER represents the Error Running Total field.
The sixth INTEGER represents the Event Running Total field.