©2018 ACP, Inc.
Cedar Rapids, IA 52404 Page 44 of 80
Part No. 16400033
Original Instructions
Measuring Procedure
1. Fill the glass beaker with 275 ml of cool water and place in
center of oven. Close door.
2. After oven has preheated, press the Blue Menu Icon.
3. Press the Manual Recipe option
4. Enter cooking time by pressing the Time Entry Box 4-6.
A number pad will appear. Enter 30 seconds Cook Time.
5. Press the “OK” Icon.
6. Select desired microwave power by pressing Microwave Power
Entry Box. Enter 100%
7. Select desired fan speed by pressing the Fan Speed Entry Box.
Enter 0%.
8. Press the Green Check Mark to begin.
9. Move the Meter Probe at 1”/sec. over all door/oven gaps.
NOTE: Water must be changed every 30 seconds to prevent boiling. If
water boils the results may be inaccurate.
10. Make a note of any area that exceeds 4mW/cm2.
11. Return the probe to any “spike areas” and allow it to remain for
17 seconds. Make a note of the highest reading.
12. When test is complete, open door and dispose of water.
Oven Tests
3