EasyManua.ls Logo

ACV HeatMaster 201 - Maintenance Safety, Tools, and Schedule

ACV HeatMaster 201
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAFETY INSTRUCTIONS FOR THE BOILER MAINTENANCE
Essential recommendations for the electrical safety
Turn off the boiler by pushing on the ON/OFF master switch.
Isolate the external power supply of the appliance before performing any
operation, unless it is required to take measurements or perform system setup.
Essential recommendations for safety
Water flowing out of the drain valve may be extremely hot and could cause severe
scalding.
Check the tightness of the flue pipe connections.
Essential recommendations for the correct operation of the appliance
It is recommended to have the boiler and the burner serviced at least once a year or
every 1,500 hours. More frequent servicing may be required depending on boiler
use. Please consult your installer for advice.
The boiler and burner maintenance will be carried out by a qualified engineer, and
the defective parts may only be replaced by genuine factory parts.
Control the tightness of the hydraulic circuit connections.
Make sure to replace the gaskets of the removed items before reinstalling them.
GAS
pressure
(mbar)
HeatMaster 201: A1004320 - 664Y7500 • A
EN
FR
NL
ES
IT
DE
PL
RU
en
33
MAINTENANCE
TOOLS REQUIRED FOR MAINTENANCE
PERIODIC APPLIANCE MAINTENANCE TASKS
Tasks
Frequency
Periodic
inspec-
tion
1 year 2 years
End-user Professional
1. Make sure that the system water pressure is at least 1 bar
when cold. Top up the system if necessary, adding small
quantities of water at a time. In case of repeated lls, call
your installer.
X X
2. Check that there is no water on the oor under the appli-
ance. Call your installer if there is.
X X
3. Check that no error code is displayed on the control panel.
Call your installer if necessary.
X X
4. Check that all gas, hydraulic and electrical connections are
correctly fastened and tight.
X
5. Check the ue gas exhaust: correct fastening, correct in-
stallation, no leaks or clogging.
X
6. Check that there is no discoloured or cracked area on the
burner chamber plate .
X
7. Check the combustion parameters (CO and CO2), see
“Checking and Adjusting the Burner” on page 32.
X
8. Check visually the heating body: no evidence of corrosion,
soot deposits or damages. Carry out all required cleaning
tasks, repairs and replacements that might be required.
X
9. Check visually the burner insulation condition. Replace if
cracked or damaged. Refer to “Removal and Installation of
the Burner” on page 34.
X
10. Check the electrode, see “Removal, Check and Installation
of the Burner Electrode”, page 35.
X
APPLIANCE SHUT DOWN FOR MAINTENANCE
1. Switch the appliance o using the ON/OFF master switch and isolate the external power supply.
2. Close the gas supply valve of the appliance.
SAFETY INSTRUCTIONS FOR THE MAINTENANCE

Table of Contents

Other manuals for ACV HeatMaster 201

Related product manuals