18
4) Once the preprogrammed percentage of extraction (dryness level) is reached, the drying cycle will
end, and the Cycle In Progress portion of the light emitting diode (L.E.D.) display will read COOL
06 MIN REMAIN and will also display the dRUM TEMP___F. (FLASH [PL5] must be active
for the “dRUM TEMP” to display. If NFLASH is active then press “ENTER/START” Key to
display “dRUM TEMP.”)
5) Once the Cool Down Cycle is completed, the dryer will shut off, the tone (buzzer) will sound (i.e.,
7-seconds), and the L.E.D. display will read “dONE.” The L.E.D. display will continue to read
“dONE” until the main door is opened.
6) If the Anti-Wrinkle Program is active (on), once the drying cycle and cooling cycles are completed
and the L.E.D. display reads “dONE” the Phase 6 OPL microprocessor controller (computer) will
proceed into the Anti-Wrinkle Program, L.E.D. displays “START GUARd.” If the main door
is not
open within the Anti-Wrinkle Delay Time (i.e., 90-seconds), the basket (tumbler) will rotate (without
heat) for the programmed Anti-Wrinkle On Time (i.e., 20-seconds). The Phase 6 OPL microprocessor
controller (computer) will repeat this process until the programmed Maximum Anti-Wrinkle On
Time has expired (i.e., 10 minutes) or until the main door is opened, whichever comes first. The
L.E.D. display will continue to read “dONE” until either the main door is opened or the Maximum
Anti-Wrinkle On Time has expired, at which time the L.E.D. display will read “dONE” until the
main door is opened.
b. Timed (Manual) Drying Cycle
1) L.E.D. display reads “REAdY” (no cycle in progress).
2) Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., Key “D”).
3) The dryer will then start (rotate).
4) The L.E.D. display will read CYCLEd, __MIN REMAIN, dRUM TEMP___F. (FLASH [PL 5]
must be active for the “dRUM TEMP” to display. If NFLASH is active then press “ENTER/
START” Key to display “dRUM TEMP.”)
NOTE: To stop the dryer at any time, open the main door. To continue the cycle, close the main door,
the Phase 6 OPL microprocessor controller (computer) prompts the operator to “PRESS
START” then press the “ENTER/START” Key. The dryer will continue from where it left
off, or ... the dryer may also be stopped by pressing the “CLEAR/STOP” Key. However,
the cycle that was in progress will be cancelled, and the L.E.D. display will return to the
“REAdY” (no cycle in progress) Mode.
5) When the programmed drying time has expired, the Phase 6 OPL microprocessor controller
(computer) will proceed into the Cool Down Cycle (Mode), and the Cycle In Progress portion of
the L.E.D. display will read COOL 06 MIN REMAIN and also display dRUM TEMP___F. (FLASH
[PL5] must be active for the “dRUM TEMP” to display. If NFLASH is active then press “ENTER/
START” Key to display “dRUM TEMP.”)
6) Once the Cool Down Cycle is completed, the dryer will shut off, and the L.E.D. display will read
“dONE.” The L.E.D. display will continue to read “dONE” until the main door is opened.