52
Program Location 0 - (Key “0”) Lint Count, Anti-Wrinkle Active, Anti-Wrinkle Buz (Tone) Active, Anti-Wrinkle
On Time 20-seconds, Anti-Wrinkle Delay Time 90-seconds, Maximum
Anti-Wrinkle Time
B. PARAMETERS (PROGRAMS) PRESET BY FACTORY FOR (OPTIONAL)
REVERSING DRYERS
CYCLE A:
Automatic Mode, Reverse, Anti-Wrinkle Active, Dry Temperature 180º F, Dryness Level 100%, Cool
Down Time 6 minutes, Cool Down Temperature 80º F, A Factor, b Factor.
CYCLE B:
Automatic Mode, Reverse, Anti-Wrinkle Active, Dry Temperature 180º F, Dryness Level 98% Cool Down
Time 6 minutes, Cool Down Temperature 80º F, A Factor, b Factor.
CYCLE C:
Automatic Mode, Reverse, Anti-Wrinkle Active, Dry Temperature 160º F, Dryness Level 98%, Cool Down
Time 4 minutes, Cool Down Temperature 80º F, A Factor, b Factor.
CYCLE D:
Manual (Timed) Mode, Reverse, Anti-Wrinkle Active, Dry Time 40 minutes, Dry Temperature 190º F, Cool
Down Time 6 minutes, Cool Down Temperature 80º F, Spin Time 60-seconds, Stop (Dwell) Time 5-seconds.
CYCLE E:
Manual (Timed) Mode, Reverse, Anti-Wrinkle Active, Dry Time 30 minutes, Dry Temperature 180º F, Cool
Down Time 4 minutes, Cool Down Temperature 80º F, Spin Time 60-seconds, Stop (Dwell) Time 5-seconds.
CYCLE F:
Manual (Timed) Mode, Reverse, Anti-Wrinkle Active, Dry Time 10 minutes, Dry Temperature 170º F, Cool
Down Time 2 minutes, Cool Down Temperature 80º F, Spin Time 60-seconds, Stop (Dwell) Time 5-seconds.
SYSTEM PARAMETERS/PROGRAMS
Program Location 2 - (Key “2”) Specific Heat selection (GAS, STEAM, ELECTRIC), Temperature Conversion
Status (set in Fahrenheit), Select Reverse, Rotational Sensor (non-active),
Factor “A” and Factor “b” (set for your particular model dryer and should
not be changed).
Program Location 5 - (Key “5”) NFlash - Auto
NFlash - Man
Flash - Auto
Flash - Man
Program Location 8 - (Key “8”) Timed (Manual) (Automatic) drying mode Cool Time 6 Minutes, Cool
Temperature 80º F, Spin Time 60-seconds, Stop (Dwell) Time 5-seconds, Buz
(Tone) Time 7-seconds.
Program Location 0 - (Key “0”) Lint Count, Anti-Wrinkle Active, Anti-Wrinkle Buz (Tone) Active, Anti-Wrinkle
On Time 20-seconds, Anti-Wrinkle Delay Time 90-seconds, Maximum
Anti-Wrinkle Time 10 minutes.