54
SECTION IX
PHASE 6 OPL PROGRAMMING LIMITS
A. PREPROGRAMMED CYCLES
1. Automatic Cycle (Mode) (Patent No. 4,827,627)
a. Drying Temperature (“dRY TEMP”) from 160º F to 200º F in one-degree increments.
b. Dryness Level (percentage of dryness (“dRY LEVEL”) from 90% to 100% in one-percent increments.
c. Cool Down Time (“COOL TIME”) from 0 to 99 minutes in one-minute increments.
d. Cool Down Temperature (“COOL TEMP”) from 70º F to 100º F in one-degree increments.
2. Timed (Manual) Drying Cycle (Mode)
a. Drying Temperature (“dRY TEMP”) from 100º F to 200º F in one-degree increments.
b. Drying Time (“dRY TIME”) from 0 to 99 minutes in one-minute increments.
c. Cool Down Time (“COOL TIME”) from 0 to 99 minutes in one-minute increments for preprogrammed
cycle.
d. Cool Down Temperature (“COOL TEMP”) from 70º F to 100º F in one-degree increments.
e. Reversing Models.
1) Automatic Cycle (Patent No. 4,827,627) is not programmable. Refer to Fixed Parameters on
page 55.
2) Timed Cycle
a) Spin Time (“SPIN TIME”) from 30-seconds to 120-seconds in one-second increments.
b) Stop (Dwell) Time (“STOP TIME”) from 5-seconds to 10-seconds in one-second increments.

Table of Contents