NCT-04/03/02 Punch CNC System (Commissioning Manual)
Blanking detection time ms Unit: ms; alarm and pause if not detected within this time
3.4 Automatic Lubrication Function
System integrates two sets of automatic lubrication systems, progressive and displacement;
3.4.1 Progressive
Parameter Description
A: lubrication cycle P1.052
B: lubrication time P1.053
C: lubrication output port P5.023
D: lubrication detection input port P5.061
E: lubrication oil pressure detection level P1.055
A: lubrication cycle, B: lubrication time, C: lubrication output port and D: lubrication detection input port (if
lubrication pulse signal is not detected within the specified time, the lubrication indicator will flash and alarm)
Note: If P1.052 is non-zero, the system automatically starts lubrication
If no alarm is detected by the lubrication detection port, press and hold "Cancel" to clear;
Set P5.061 to 8888 to shield the alarm;
3.4.2 Displacement
Parameter Description
A: lubrication cycle P1.137
B: lubrication time P1.138
C: lubrication output port P5.062
D: lubrication detection input port P5.062
E: lubrication oil pressure detection level P1.140
A: lubrication cycle, B: lubrication time, C: lubrication output port and D: lubrication detection input port (if
lubrication pulse signal is not detected within the specified time, the lubrication indicator will flash and alarm)
Note: If P1.137 is non-zero, the system automatically starts lubrication
If no alarm is detected by the lubrication detection port, press and hold "Cancel" to clear;
Set P5.062 to 8888 to shield the alarm;