Parameter Description
C220/C420G General Flux Vector Control Inverter User Manual
88
setup range
0.00
65.535Ω
F4-09
Rotor resistance
factory default
value
model
dependent
setup range
0.00
65.535Ω
F4-10
Mutual inductive
reactance
factory default
value
model
dependent
setup range
0.1mH
6553.5mH
F4-11
Leakage inductive
reactance
factory default
value
model
dependent
setup range
0.01 mH
65.535mH
F4-12
Complete tuning
acceleration
factory default
value
5000
setup range
1
60000
F4-13
Complete tuning
deceleration
factory default
value
5000
setup range
1
60000
caution
1Please set this parameters according to the nameplate parameters of the motor
2It needs accurate motor parameter to ensure the excellent control performance of
the vector control. Accurate parameter identification comes from the correct
setting of the rated motor parameters.
3In order to ensure the control performance ,please carry out motor configuration
in accordance with the standard adaptable motor on the inverter. If there is
huge difference between the motor power and the power of standard adaptable
motor, the control performance on the inverter will decrease obviously.