Parameter Description
C220/C420G General Flux Vector Control Inverter User Manual
87
stops flashing. After the tuning is completed, the display will return back to stop
status interface ,In the process of tuning, pressing this STOP key can be stopped
The value of F4-00 will automatically restore to 0 at the end of tuning.
F4-01
Rated power
factory default
value
model dependent
setup range
0.4kw
1000.0kw
F4-02
Rated voltage
factory default
value
380V
setup range
0V
440V
F4-03
motor poles
factory default
value
4
setup range
2
64
F4-04
Rated current
factory default
value
Models to determine
setup range
0.00A
3000.0A
F4-05
Rated frequency
factory default
value
50.00Hz
setup range
0.00Hz
The maximum frequency
F4-06
Rated rotation
speed
factory default
value
1460rpm
setup range
0 rpm
30000rpm
F4-07
No load current
factory default
value
model
dependent
setup range
0.1A
1500.0A
F4-08 Stator resistance
factory default
value
model
dependent