Ground Resistance Tester Model 6471
2.3 Control Features
GROUND TESTER
MODEL 6471
2 3
4
1
5
7
6
Figure 2-1
1. Four terminals: H (Z) (auxiliary electrode), S (Y) (electrode), ES (Xv) (earth/
ground electrode) and E (X) (earth/ground electrode)
All terminals accept 4mm Ø banana plugs. Terminals H (Z) and ES (Xv) also
accept special plugs for current clamps. S (Y) will take a shielded cable.
2. Connector for charging the battery (see § 9.4).
3. 256 segment multi-line backlit LCD (see § 2.4).
4. Connector for an optical interface to a PC. Either an RS-232 or USB connec-
tion can be used (see § 8 - DataView
®
).
5. Rotary switch: OFF position, 5 measurement functions (see § 5 and 6) and
SET-UP function (see § 4.2).
6. START/STOP button: Starts the measurement and compensates for the leads
(in the mΩ measurement function - see § 5.2.1).
7. Six function buttons (see § 2.5).