11
After accessing the “Heat+hot water” function, you
can select “Heat to force the unit to first of all satisfy
the system terminal side; by selecting “Hot water”, pri-
ority is given to domestic hot water production. Select
the priority, then press “OK” to confirm.
Heat + hot water
Hot water
Heat
OK Cancel
NOTES:
1. If the compatible Aermec accessory tank for this model (refer to the installation manual for more
information) is not installed and correctly set, this function will not be available.
2. If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
3. The default value for this parameter is: “Heat”.
4.5. Set the priority between heating and domestic hot water production (Heat+hot water)
After accessing the “Quiet mode function by clicking
on the label, you can change the value to be assigned
to the function. The possible values are:
“On = Function active
“Off = Function not active
“Clock timer” = Function active but in accord-
ance with the time settings provided
If you select “Clock timer, two keys will appear. Use
them to set the start and end of the “Quiet mode” acti-
vation period. To set the values, press the time label in
question and set the hours and minutes by sliding the
value up or down with your fingertip (the value high-
lighted in blue in the middle of the selection window),
as shown in the figure:
00 00
01 01
02 02
23 59
22 58
Quiet mode
Quiet mode: Timer
Start Timer: 00:00
End Timer: 00:00
NOTES:
1. Every time you press on the label, the value will change. Once you have selected the required value,
press the icon to save and implement the setting.
2. The function can still be set if the unit is Off, but it will only be implemented if the unit is activated.
3. When the function is set to On, it will automatically be set to “Off if the unit is switched off manu-
ally, whereas the setting will remain valid until the end of the selected period if the function value is
set to “Clock timer”.
4. If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
5. The default value for this parameter is: “Off”.
00 00
01 01
02 02
23 59
22 58
Quiet mode
Quiet mode: Timer
Start Timer: 00:00
End Timer: 00:00
4.6. Setting the noise reduction function (Quiet mode)