NOTES:
1. Every time you press on the label, the value will change. Once you have selected the required value,
press the icon to save and implement the setting.
2. To make the time settings specified on various days of the week effective, the Weekly Timer must be
set to “On (by clicking on the Weekly Timer label itself ).
3. The “With setting for one or more days of the week validates the specified time settings only if the
Weekly Timer is “On.
4. You can set up to three time bands (periods) for each day; their start and end times must be coherent
(the start of one period must be later than the end of the previous one).
5. If one day or more has been set as Holiday, you must activate the “Holiday release function (ex-
plained in the next paragraph).
6. If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
7. The default value for this function is “Off”.
Holiday release
On
Off
OK Cancel
NB:
1. if one day or more is set on Holiday in the weekly timer, this function must be “On” if you want the
program specified in the timer to be respected.
2. The default value for this function is “Off”.
4.9. Enabling the Holiday Program function used for the weekly timer (Holiday release)
After accessing the “Holiday release function, you can
enable or disable this program if applied as a daily set-
ting on one or more days of the weekly timer. Select
the setting, then press “OK” to confirm.
After accessing the “Disinfection function, you can
enable or disable this function, as well as choose the
time and day to run it and the temperature to be used.
WARNING: if the unit is used for domestic hot water
production, the Disinfection MUST necessarily be
used.
00 00
01 01
02 02
23 59
22 58
Disinfection
Disinfection: Off
Set clock: 23:00
Set temp.: 70°C
Set day: Mon.
4.10. Enabling/disabling the anti-legionella cycle (Disinfection)