15
NOTES:
1. Every time you press on the label, the value will change. Once you have selected the required value,
press the icon to save and implement the setting.
2. If the compatible Aermec accessory tank for this model (refer to the installation manual for more
information) is not installed and correctly set, this function will not be available.
3. This function can only be activated if the unit is switched off.
4. This function cannot be activated simultaneously with: “Emergen. mode”, “Holiday mode“, “Floor de-
bug“, “Manual defrost“, “Refri. recovery“.
5. If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
6. If the anti-legionella cycle is not completed, the unit will produce a message on the screen to indi-
cate the anomaly. This message can be reset by pressing “OK”.
7. An anti-legionella cycle will automatically be interrupted by any possible communication error or an
error linked to the storage tank accessory.
8. If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
9. The default value for this function is “Off”.
00 00
01 01
02 02
23 59
22 58
Disinfection
Disinfection: Off
Set clock: 23:00
Set temp.: 70°C
Set day: Mon.
Min: 40 Max: 70
X
0
1 2 3
4 5 6
7 8
0 -
9
OK
Click on the label relating to the set-point value for
the anti-legionella cycle. This will draw up a numerical
keypad, that you can use to alter the set-point (within
the permitted ranges). Bear in mind that to ensure the
effectiveness of the cycle, it will be maintained for a
certain duration which will increase when the set val-
ue is decreased.