EasyManua.ls Logo

Agilent Technologies 16900 Series

Agilent Technologies 16900 Series
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
130 16900 Series Logic Analysis Systems Installation Guide
7 Solving Problems
If there are multiframe connection problems
All 1 Gbit LAN cards in a multiframe set up must be set with the same
Jumbo Frames setting. Also, if a switch/hub is used, you must ensure that
it supports the same size Jumbo Frame setting. If all 1 Gbit LAN cards
are not set with the same Jumbo Frames setting, you might get error
messages indicating so.
One or more of the frames is not completely initialized yet... Please wait
a few seconds.
To check the Jumbo Frames setting:
1 Choose Start>Control Panel. In the Control Panel window, open
Network Connections.

Table of Contents