2-48 Agilent B1500 VXIplug&play Driver User’s Guide, Edition 3
Driver Functions
agb1500_setCmuAdjustMode
agb1500_setCmuAdjustMode
This function selects the phase compensation mode of the MFCMU. After this
function, the MFCMU is initialized.
Syntax ViStatus _VI_FUNC agb1500_setCmuAdjustMode(ViSession vi, ViInt32 channel,
ViInt32 mode);
Parameters vi Instrument handle returned from agb1500_init( ).
channel Slot number of the slot that installs the MFCMU to be used. See
Table 2-2. channel=-1 detects the slot automatically.
mode 0: Auto mode. The B1500 sets the compensation data
automatically.
1: Manual mode. Execute the agb1500_execCmuAdjust
function to perform the phase compensation and set the
compensation data.
agb1500_setCmuFreq
This function sets the frequency of the AC voltage forced by the MFCMU. The AC
voltage output will be triggered by the agb1500_forceCmuAcLevel.
Syntax ViStatus _VI_FUNC agb1500_setCmuFreq(ViSession vi, ViInt32 channel,
ViReal64 value);
Parameters vi Instrument handle returned from agb1500_init( ).
channel Slot number of the slot that installs the MFCMU to be used. See
Table 2-2. channel=-1 detects the slot automatically.
value Frequency (in Hz). Numeric expression.
1000 (1 kHz, initial setting) to 5000000 (5 MHz)
Setting resolution: 1 mHz (1 kHz to), 10 mHz (10 kHz to),
0.1 Hz (100 kHz to), or 1 Hz (1 MHz to 5 MHz).
agb1500_setCmuInteg
This function sets the number of averaging samples or the averaging time set to the
A/D converter of the MFCMU.

Table of Contents

Other manuals for Agilent Technologies B1500A

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies B1500A and is the answer not in the manual?

Agilent Technologies B1500A Specifications

General IconGeneral
TypeSemiconductor Device Analyzer
ModelB1500A
Maximum Voltage200 V
Number of SMUsUp to 10
Frequency RangeDC to 1 MHz
ConnectivityUSB, LAN
ChannelsUp to 10
InterfaceGUI

Summary

Installation

System Requirements

Details the necessary hardware and software for the driver.

Installing VXIplug&play Driver

Provides a step-by-step guide for installing the driver.

Before Programming

Covers pre-programming setup and configuration steps.

Driver Functions

Function List

Lists all available driver functions with brief descriptions.

Parameters

Details the parameters used by various driver functions.

Status Code

Describes the status codes returned by measurement functions.

Function Reference

Provides detailed descriptions and syntax for each driver function.

Visual Basic Programming Examples

Programming Basics

Basic information and steps for programming with the driver.

High Speed Spot Measurement Example

Example demonstrating high-speed spot measurement using Visual Basic.

Staircase Sweep Measurement Example

Example for staircase sweep measurements.

Breakdown Voltage Measurement Example

Example for measuring breakdown voltage.

Leakage Current Measurement Example

Example for measuring leakage current.

C++ Programming Examples

Programming Basics

Basic information and steps for C++ programming.

High Speed Spot Measurement Example

Example demonstrating high-speed spot measurement in C++.

Staircase Sweep Measurement Example

Example for staircase sweep measurements in C++.

Breakdown Voltage Measurement Example

Example for measuring breakdown voltage in C++.

Leakage Current Measurement Example

Example for measuring leakage current in C++.

Sampling Measurement Example

Example for sampling measurement in C++.

CV Sweep Measurement Example

Example for CV sweep measurement in C++.

Related product manuals