User’s and
Installation Manual
Dry Vacuum System
RECOMMEND DAILY
USE OF
MONARCH
CLEANSTREAM

Questions and Answers

  • A
    Amy HuangJul 31, 2025
    What to do if the room temperature is above 105°F for Air Techniques MOJAVE LT3 Medical Equipment?
    • J
      Joshua YoungAug 1, 2025
      If the room temperature exceeds 105°F, it is likely due to inadequate ventilation in the equipment room. Ensure the ambient temperature is not above 105°F and increase ventilation in the equipment room if needed.
  • A
    Amanda JacobsonAug 5, 2025
    What to do if the Separator is below minimum speed in Air Techniques MOJAVE LT3 Medical Equipment?
    • D
      Dana BrownAug 5, 2025
      If the separator is below minimum speed, try the following: 1. If a large amount of liquid has entered the Separator, try turning the pump on again. 2. Check that the separator fan is spinning when the pump is turned on. 3. Verify the hall effect sensor cable is not loose at the back of the unit.
  • A
    amyrobertsAug 9, 2025
    What to do if the vacuum level value is more than 1.0 inHg over setpoint in Air Techniques MOJAVE LT3 Medical Equipment?
    • P
      Paul AlvarezAug 9, 2025
      If the vacuum level value is more than 1.0 inHg over the setpoint, check that the control board is not in 'Bypass' mode.
  • N
    Nichole FloydAug 13, 2025
    Why is the line voltage out of range for Air Techniques Medical Equipment?
    • M
      mullinsmatthewAug 13, 2025
      The line voltage may be out of range due to voltage dips or spikes on the AC Mains, or if the unit is installed on a 120 VAC circuit. Ensure the pump is on a dedicated 220 VAC circuit.
  • J
    Joel StevensAug 17, 2025
    How to fix high room temperature for Air Techniques Medical Equipment?
    • D
      ddelacruzAug 18, 2025
      If the room temperature is too high, this could be caused by inadequate ventilation in the equipment room or restricted exhaust lines. Check that the ambient temperature is not above 105°F. Increase the ventilation in the equipment room if necessary. Also, check that the exhaust lines are not blocked or restricted.
  • C
    Charles ArmstrongAug 22, 2025
    What does it mean when a Motor VFD error is detected in Air Techniques MOJAVE LT3 Medical Equipment?
    • B
      brandtrachelAug 22, 2025
      If a Motor VFD error is detected, check for the VFD error code under the 'Settings -> Info' screen.
  • M
    Meagan JonesAug 27, 2025
    What causes low room temperature for Air Techniques MOJAVE LT3 Medical Equipment?
    • J
      Joseph AndradeAug 27, 2025
      If the room temperature is too low, it may be caused by inadequate insulation of the equipment room. Check that the ambient temperature in the equipment room is above 40°F. Increase heating to the equipment room if necessary.

Summary

CONGRATULATIONS

SAFETY SUMMARY

Key safety precautions and warnings for unit operation.

SPECIFICATIONS

INSTALLATION INFORMATION

Site Requirements: Electrical

Specifications for the electrical supply and wiring.

Site Requirements: Plumbing

Specifications for plumbing connections and drain lines.

INSTALLATION

Connection Procedure Overview

General instructions for connecting the LT3 unit.

Drain to Facility Sewer Connection

Procedure for connecting the separator drain to the sewer.

ELECTRICAL CONNECTIONS

Pump Direct Power Connection

How to connect the main 220V power supply to the pump.

OPERATING INFORMATION

General Operation Overview

How the system runs, standby mode, and remote operation.

Startup via Touch Screen

Steps to start the unit using the LCD touch screen.

Pump Power Switch Function

Explanation of the main power switch and circuit breaker.

Startup via Remote Switch

Steps to start the unit using an optional remote switch.

TOUCH SCREEN CONTROLS

Alarm Notifications

How warnings and errors are displayed on the screen.

Error Conditions

List of critical errors and their immediate actions.

Warning Conditions

List of specific conditions that trigger warnings.

MAINTENANCE

Daily Vacuum Line Cleaning

Procedure using CleanStream Cleaner for daily maintenance.

TROUBLESHOOTING

Warning Message Solutions

Table of warnings, causes, and recommended solutions.

Error Message Solutions

Table of errors, causes, and recommended solutions.

WARRANTY

Air Techniques MOJAVE LT3 Specifications