EasyManua.ls Logo

AJP PR7 - Recharging the Battery

AJP PR7
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D.21
ELECTRIC SYSTEM
Note: The battery must be recharged with
an automatic battery charger. The
charger should turn off when the battery
voltage is 14.4 V.
RECHARGING THE BATTERY
Motorcycles stored for long periods or equipped with additional electronic accessories will cause
battery discharge.
The battery should be charged when identified issues as instrument panel malfunction,
electronic starter motor malfunction or engine power loss due the injection system errors.
In case of home battery recharge:
Remove the battery (see REMOVING THE BATTERY);
Place the battery in a clean, dry and ventilated area. Keep out of ignition sources or
inflammable substances;
Inspect the battery charger. Ensure that it is in good conditions and set with right
values;
Connect first the terminal clamps in the battery. Then plug the charger to a 110 VAC
- 220 VAC electric network;
Check the voltage. The battery voltage should be in 13.9 V to 14.4 V range.
WARNING
Do not let the battery voltage drop below 13.1 V. Improper voltage can lead to
problematic starts, fuel injection system errors or performance loss.
Use a recommended charger. Incorrect charger configurations can damage or
destroy the battery.
Normal 1.4 A
5 ~ 10
Hours
Fast 14 A 1 Hour
Recharge
method
Recharge
current
Recharge
time

Related product manuals