34
Relay ID: R29 series supports three relays. Users can configure
them respectively.
Trigger Delay: To configure the duration of the trigger relay. With
the trigger condition, the relay will only be triggered if the value is
reached.
Hold Delay: To configure the duration of opened relay. Over the
value, the relay would be closed again.
DTMF Option: To select digit of DTMF code, R29 series supports
maximum 4 digits DTMF code.
DTMF: To configure 1 digit DTMF code for remote unlock
Multiple DTMF: To configure multiple digits DTMF code for remote
unlock.
Relay Status: While the relay is triggered, the statues will be
switched. When COM connects to NC, the status is Low.
Note: Relay operate a switch and does not deliver power, so users
should prepare power adapter for external devices which connects
to relay.
Figure 3.8.1 Relay

Table of Contents

Other manuals for Akuvox R29 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Akuvox R29 Series and is the answer not in the manual?

Akuvox R29 Series Specifications

General IconGeneral
PowerPoE or 12V DC
Operating SystemAndroid
RS485Yes
WiegandYes
InstallationWall-mounted
Tamper-proofYes
ProcessorQuad-Core
RAM2GB
Display7-Inch LCD
Camera2MP
NetworkEthernet
IntegrationSIP, ONVIF
Light compensationYes
Ethernet10/100M
PoE802.3af
Operating Humidity10% to 90% (non-condensing)
Storage8GB
ProtocolsSIP, ONVIF, RTSP

Related product manuals