Interface Configuration
7750 SR OS Interface Configuration Guide Page 107
Operators may sometimes require the capability to query the system for the link in a LAG or
Ethernet tunnel that is currently assigned to a given service-id or ISID. This ability is provided
using the tools>dump>map-to-phy-port {ccag ccag-id | lag lag-id | eth-tunnel tunnel-index}
{isid isid [end-isid isid] | service servid-id | svc-name [end-service service-id | syc-name]}
[summary] command.
A sample usage is as follows:
A:Dut-B# tools dump map-to-phy-port lag 11 service 1
ServiceId ServiceName ServiceType Hashing Physical Link
---------- ------------- -------------- ----------------------- -------------
1 i-vpls per-service(if enabled) 3/2/8
A:Dut-B# tools dump map-to-phy-port lag 11 isid 1
ISID Hashing Physical Link
-------- ----------------------- -------------
1 per-service(if enabled) 3/2/8
A:Dut-B# tools dump map-to-phy-port lag 11 isid 1 end-isid 4
ISID Hashing Physical Link
-------- ----------------------- -------------
1 per-service(if enabled) 3/2/8
2 per-service(if enabled) 3/2/7
3 per-service(if enabled) 1/2/2
4 per-service(if enabled) 1/2/3