Configuration Commands
Page 432 7750 SR OS Interface Configuration Guide
Eth Tunnel Commands
eth-tunnel
Syntax eth-tunnel tunnel-id
no eth-tunnel
Context config
Description This command configures a G.8031 protected Ethernet tunnel.
The no form of this command deletes the Ethernet tunnel specified by the tunnel-id.
Default no eth-tunnel
Parameters tunnel-id — Specifies the tunnel ID.
Values 1 — 64
ccm-hold-time
Syntax ccm-hold-time {down down-timeout | up up-timeout}
no ccm-hold-time
Context config>eth-tunnel
Description This command configures eth-tunnel CCM dampening timers.
The no form of the command reverts to the default.
Default no ccm-hold-time
Parameters down down-timeoutSpecfies the eth-tunnel CCM down timers.
Values 0 — 1000 in 100ths of seconds
Default 0
up up-timeoutSpecfies the eth-tunnel CCM up timers.
Values 0 — 5000 in 10ths of seconds
Default 20
description
Syntax description long-description-string
no description