EasyManua.ls Logo

Alcatel-Lucent 7750 SR OS - Page 459

Alcatel-Lucent 7750 SR OS
628 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interface Configuration
7750 SR OS Interface Configuration Guide Page 459
src-mac
Syntax src-mac ieee-address
no src-mac
Context config>redundancy>mc>peer>mcr>node>cv
Description This command specifies the source MAC address used for the Ring-Node Connectivity Verification
of this ring node.
A value of all zeroes (000000000000 H (0:0:0:0:0:0)) specifies that the MAC address of the system
management processor (CPM) is used.
Default no src-mac
Parameters ieee-address — Specifies the source MAC address.
vlan
Syntax vlan [vlan-encap]
no vlan
Context config>redundancy>mc>peer>mcr>node>cv
Description This command specifies the VLAN tag used for the Ring-node Connectivity Verification of this ring
node. It is only meaningful if the value of service ID is not zero. A zero value means that no VLAN
tag is configured.
Default no vlan
Parameters vlan-encap — Specifies the VLAN tag.
Values vlan-encap: dot1q qtag
qinq qtag1.qtag2
qtag 0 — 4094
qtag1 1 — 4094
qtag2 0 — 4094

Table of Contents