A:ALA-49>config>port# show port 3/2/1 otu detail
===============================================================================
OTU Interface
===============================================================================
OTU Status : Enabled FEC Mode : enhanced
Data Rate : 11.049 Gb/s
Cfg Alarms : loc los lof lom otu-ber-sf otu-bdi fec-sf
Alarm Status :
SF/SD Method : FEC SF Threshold : 1E-5
SD Threshold : 1E-7
SM-TTI Tx (auto) : ALA-49:3/2/1/C17
SM-TTI Rx : (Not Specified)
===============================================================================
OTU Statistics
===============================================================================
Statistics Count
-------------------------------------------------------------------------------
FEC Corrected 0s 0
FEC Corrected 1s 0
FEC Unrrectable Sub-rows 0
FEC SES 0
SM BIP8 0
SM BEI 0
FEC Corrected 0s
Displays the number of bits that were received as 0s but corrected to
1s.
FEC Corrected 1s
Number of bits that were received as 1s but corrected to 0s.
FEC Uncorrectable
Sub-Rows
The number of sub-rows that were not corrected because too many
errors were detected.
FEC SES
The number of severely errored seconds were the number of uncorrect-
able sub-rows was greater than 15% of the maximum.
SM BIP8
The number of detected BIP-8 errors in the section monitor overhead.
SM BEI
The number of backward error indications received from the far end in
the section monitor overhead.
SM SES
Section monitor severely errored seconds where the number of SM-
BIP8 was greater than 15% of the maximum.
PM BIP8
The number of detected BIP-8 errors in the section monitor overhead.
PM BEI
The number of backward error indications received from the far end in
the section monitor overhead.
PM SES
Section monitor severely errored seconds where the number of SM-
BIP8 was greater than 15% of the maximum.
Label Description (Continued)