password in OMC
Prerequisites
- The Alcatel-Lucent OmniPCX Office Communication Server version must be R810 or
higher and the system must be operational
- For network configuration, any of the following must be implemented:
In dynamic mode, a DHCP server must be configured
In static mode, a free IP address must be available for the set
- A port with PoE must be available on a switch. If not available, a PoE injector must be
used
Configuring the user in OMC
Note:
In dynamic (DHCP) mode, 8082 My IC Phone sets are fully plug & phone. This operation is not
mandatory.
To create an 8082 My IC Phone:
1. In OMC, go to Users/Base stations List.
2. Select a No., IP access and click the Add button.
3. Select IP terminal and click OK.
4. Select the newly created user in the list, select 8082 My IC Phone in the combo box type
and enter a name.
5. Click the Modify button.
6. Double-click the newly created user to open the User dialog box.
7. Click the IP/SIP button and enter the MAC address of the set in the IP Parameters tab.
8. If needed, in the SIP Parameters tab, click the SIP password reset button to get a new
password.
Connecting the set
This section describes how to:
- Connect an 8082 My IC Phone set to the LAN (Local Area Network)
- Connect the external power adapter, if necessary
Note:
The external power adaptor is compatible with 8082 My IC Phone HW2, it is not compatible with version
HW1.
Connecting an 8082 My IC Phone set to the LAN
To connect the set to the LAN:
- If you are using the 8082 Power Over Ethernet Injector Kit:
a. Plug an RJ45 cable between the data in port of the kit and the LAN
b. Plug an RJ45 cable between the data and power out port of the kit and the set LAN
connector
  ()
       
4-41

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Office and is the answer not in the manual?

Alcatel-Lucent OmniPCX Office Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Humidity10% to 90% non-condensing
TypeIP PBX
Maximum TrunksUp to 60
Voice codecsG.711, G.729
Network Interfaces10/100 Ethernet
WeightVaries depending on the model/configuration