17. Troubleshooting Universal Network Profiles
(UNP)
Summary of the commands in this chapter is listed here:
__________________________________________________________________
show unp user
d port 1 1
mod port 1 1 PORT_VID=1
__________________________________________________________________
17.1. Troubleshooting in bShell
Example of one trouble shooting scenario:
Issue: UNP classification on SAP access port does not happen randomly on OS6900-X40
In this case, PORT_VID on port 1 value was set as "0xfff" at BCM. This causes the packet not going to CPU
for UNP classification. PORT_VID on port 19 was fine and had no issue for the user classification.
Go to maintenance shell / bShell
BCM.0> d port 1 1
PORT.ipipe0[1]:
<VT_MISS_DROP=0,VT_KEY_TYPE_USE_GLP=1,VT_KEY_TYPE_2_USE_GLP=1,VT_KEY_TYPE_2=5,VT_KEY_TYPE=4,VT_EN
ABLE=0,
VNTAG_ACTIONS_IF_PRESENT=0,VNTAG_ACTIONS_IF_NOT_PRESENT=0,VLAN_PROTOCOL_DATA_INDEX=1,VLAN_PRECEDE
NCE=0,VINTF_CTR_IDX=0,
VFP_PORT_GROUP_ID=1,VFP_ENABLE=1,V6L3_ENABLE=1,V6IPMC_L2_ENABLE=0,V6IPMC_ENABLE=0,V4L3_ENABLE=1,V
4IPMC_L2_ENABLE=0,V4IPMC_ENABLE=0,
USE_PORT_TABLE_GROUP_ID=0,USE_IVID_AS_OVID=0,USE_INNER_PRI=0,URPF_MODE=0,URPF_DEFAULTROUTECHECK=0
,TX_DEST_PORT_ENABLE=0,TX_DEST_PORT=0,
TRUST_INCOMING_VID=1,TRUST_DSCP_V6=0,TRUST_DSCP_V4=0,TRUST_DOT1P_PTR=0,TRILL_ENABLE=0,TAG_ACTION_
PROFILE_PTR=0,SUBNET_BASED_VID_ENABLE=1,
RTAG7_PORT_LBN=0,RTAG7_HASH_CFG_SEL_TRUNK=0,RTAG7_HASH_CFG_SEL_TRILL_ECMP=0,RTAG7_HASH_CFG_SEL_LB
ID=0,RTAG7_HASH_CFG_SEL_HIGIG_TRUNK=0,
RTAG7_HASH_CFG_SEL_ECMP=0,RESERVED_1=0,RESERVED_0=0,REMOVE_HG_HDR_SRC_PORT=0,REMOTE_CPU_EN=0,PVLA
N_ENABLE=0,PROTOCOL_PKT_INDEX=2,
PROHIBITED_DOT1P=0,PRI_MAPPING=0xfac688,PORT_VID=0xfff,PORT_TYPE=0,PORT_PRI=0,PORT_OPERATION=0,PO
RT_DIS_UNTAG=0,PORT_ DIS_TAG=0,
//snip//
BCM.0> d port 19 1
PORT.ipipe0[19]:
<VT_MISS_DROP=0,VT_KEY_TYPE_USE_GLP=1,VT_KEY_TYPE_2_USE_GLP=1,VT_KEY_TYPE_2=5,VT_KEY_TYPE=4,VT_EN
ABLE=0,
VNTAG_ACTIONS_IF_PRESENT=0,VNTAG_ACTIONS_IF_NOT_PRESENT=0,VLAN_PROTOCOL_DATA_INDEX=0x13,VLAN_PREC
EDENCE=0,VINTF_CTR_IDX=0,
VFP_PORT_GROUP_ID=1,VFP_ENABLE=1,V6L3_ENABLE=1,V6IPMC_L2_ENABLE=0,V6IPMC_ENABLE=0,V4L3_ENABLE=1,V
4IPMC_L2_ENABLE=0,V4IPMC_ENABLE=0,
USE_PORT_TABLE_GROUP_ID=0,USE_IVID_AS_OVID=0,USE_INNER_PRI=0,URPF_MODE=0,URPF_DEFAULTROUTECHECK=0
,TX_DEST_PORT_ENABLE=0,TX_DEST_PORT=0,
TRUST_INCOMING_VID=1,TRUST_DSCP_V6=0,TRUST_DSCP_V4=0,TRUST_DOT1P_PTR=0,TRILL_ENABLE=0,TAG_ACTION_
PROFILE_PTR=3,SUBNET_BASED_VID_ENABLE=0,
RTAG7_PORT_LBN=0,RTAG7_HASH_CFG_SEL_TRUNK=0,RTAG7_HASH_CFG_SEL_TRILL_ECMP=0,RTAG7_HASH_CFG_SEL_LB
ID=0,RTAG7_HASH_CFG_SEL_HIGIG_TRUNK=0,
RTAG7_HASH_CFG_SEL_ECMP=0,RESERVED_1=0,RESERVED_0=0,REMOVE_HG_HDR_SRC_PORT=0,REMOTE_CPU_EN=0,PVLA
N_ENABLE=0,PROTOCOL_PKT_INDEX=2,
PROHIBITED_DOT1P=0,PRI_MAPPING=0xfac688,PORT_VID=1,PORT_TYPE=0,PORT_PRI=0,PORT_OPERATION=0,PORT_D
IS_UNTAG=0,PORT_DIS_TAG=0,
//snip//
Modified the parameter of PORT_VID in BCM. After this changes, user entry on port 1 is updated correctly