OmniSwitch OS6860/OS6900/OS10K Troubleshooting Guide Part No.032996-00 Rev.A
AOS Release 7.X and 8.X January 2015
Alcatel-Lucent Page 17 of 148
Longest Chassis uptime
Lowest Chassis ID
Lowest Chassis MAC Address
In OS6860/OS6860E auto VC, once the Master is elected the chassis connecting the lower VFL port of the
master is assigned Chassis 2 and the value increments for each additional chassis up to chassis 8.
Virtual Chassis - Boot-Up
The Master chassis contains the vcboot.cfg file that details the configuration for the entire virtual chassis. All
the switches (i.e. the one that will eventually become the Master and the ones that will become Slaves) contain
a vcsetup.cfg file that allows them to establish an initial connection over a VFL to all the other neighboring
switches.
1. Upon boot-up, a switch will read its local vcsetup.cfg file and attempt to connect to the other neighbor
switches
2. Upon connection, the switches will exchange the parameters configured in their local vcsetup.cfg files
3. As a result of this exchange, they will discover the topology, elect a Master based on criteria described
in the next section, start periodic health checks over the VFL, and synchronize their configuration as
defined within the vcboot.cfg configuration file
4. All Slaves, if they do not have a local copy of vcboot.cfg, or if their local copy does not match the
copy found on the Master, will download the vcboot.cfg from the Master chassis and reboot using this
copy of vcboot.cfg as its configuration file
Startup Error Mode
If a switch is unable to successfully come up in virtual chassis mode, it enters a special fallback mode called
start up error mode. A switch moves to start up error mode if either one of the following conditions occur:
The vcsetup.cfg and vcboot.cfg configuration files are present in the running directory, but no valid
advanced license is installed on the switch.
The vcsetup.cfg file is corrupted or edited in such a way that it is unable to read a valid chassis identifier
in the appropriate range.
A switch start up error mode will keep all of its front-panel user ports, including the virtual-fabric links
member ports disabled. This mode can be identified on the switch by using the show virtual-chassis topology
command. The chassis role will display Inconsistent, whereas the chassis status will show either one of the
following values:
Invalid-Chassis-Id: The chassis is not operational in virtual chassis mode because no valid chassis
identifier has been found in the configuration. Typically this means that the vcsetup.cfg file is corrupted,
empty or contains an invalid (e.g. out of range) chassis identifier.