Managing OmniSwitch 6350 Stacks Slot Numbering
OmniSwitch 6350 Hardware Users Guide April 2017 page 7-23
When the stack comes up following the reboot, the manually-configured slot numbers display as follows:
Stack Numbering Before Manual Assignment
The stack set slot command can also be used to manually correct duplicate saved slot assignments within
the stack topology. Refer to pages 7-12 through 7-14 for detailed information.
Reverting to the Dynamic Slot Numbering Model
To clear the boot.slot.cfg files from the stack’s /flash directories, use the stack clear slot command on all
modules and then reboot the stack. For example:
-> stack clear slot 1
-> stack clear slot 2
-> stack clear slot 3
-> stack clear slot 4
-> reload all
The commands shown above clear the saved slot information from all modules in an eight-module stacked
configuration and then reboot the stack. Because the system software no longer has preassigned slot
information to read during the boot process, the stack uses the dynamic slot number assignment method
described on page 7-20.