OmniSwitch 6855 Series Chassis and Hardware Components DC Power Supply Considerations
OmniSwitch 6855 Series Hardware Users Guide March 2009 page 2-37
DC Power Supply Considerations
In addition to the installation steps described in “Connecting a Power Supply Directly to the Chassis” on
page 3-5 and “Rack Mounting the Power Supply Tray” on page 3-6 DC power supplies have the follow-
ing additional considerations:
Connect to a -48V reliably grounded DC SELV source if using either a PS-120I80DC48 or PS-
I40DC2448 power supply.
Connect to a 24V reliably grounded DC SELV source if using a PS-100I80DC24 or PS-I40DC2448
power supply.
Use common DC return connections for the DC power supplies. The DC return terminal conductor
should be connected to the equipment frame.
The Branch Circuit Overcurrent Protection must be rated a Maximum of 15A.
Use 12AWG solid conductors only.
A readily accessible disconnect device that is suitably approved and rated shall be incorporated in the
field wiring.
Twisted pair wire (red and black) for a DC power supply
Note. Refer to the wiring diagram for information on connecting the DC power supply to a DC power
source.
Connecting a DC Power Source
The DC power supply on your switch contains a power connector with three (3) square slots for connect-
ing the positive, negative, and ground wires from a DC power source.
OmniSwitch DC Power Supply Connector
MIN 1 TURN PER 1.5
HALF TURN PER .75
Black
Red
Side Screws for Connector Removal
DC Power Connectors
+ -