5. Installing the system
5.1 Important information
The boiler must never be started without its glycol mixture. Therefore, never connect 12 V to the boiler
if there is a risk of frost, and when the vehicle is not going to be used. Otherwise, there is a risk of
freezing.
safety instructions carefully.
Burn hazard
Beware of hot surfaces when the system is in use.
Carbon monoxide poisoning
The heating system can generate dangerous carbon monoxide (CO) when using LPG as fuel, if not
correctly installed and/or used.
5.2 Installing the boiler
Boiler placement
The most suitable location for the boiler is in a wardrobe or storage compartment, but it may also be
an enclosed compartment to protect against water splashes, exhaust gases etc.
When choosing its position, remember to allow for removing the service hatch (Fig. 3, item 1). Make
be on the same side as an awning or canopy.
Installation measurements according to Fig. 3 are recommended minimum measurements for boiler
installation. The space in which the boiler is installed must be well-ventilated, with a minimum ventila-
tion area of 70 cm
2
Cut hazard
Always wear protective gloves to prevent injury caused by sharp edges during installation.
Never place the boiler in the passenger compartment of type M2 or M3 vehicles.
Fig. 3, Built-in boiler
WARNING
DANGER
min. 320 mm
min. 535 mm
min. 440 mm
2
3
1
3030, min. 520 mm
3030 Plus, min. 540 mm