56
Automatic climate control will not work satisfactorily
• Make sure the zone selected to control the AC reacts appropriately to high and low room tempera-
tures. It is possible to choose the zone which controls AC in a dual-zone system.
• Make sure you have chosen the correct control zone. To increase sensor sensitivity, use a more
open sensor (part number 3010638). If the AC will not cool due to low outdoor temperature, the
outdoor sensor can be temporarily disconnected to test the AC.
• Fitting an outdoor temperature sensor (part number 3010299) improves automatic climate control.
If the outdoor temperature is too low, the AC should not cut in at all.
14. Service information & resetting
Tap Service Information page 3/3, Fig. 30, under to reach the Service menu.
The service menu shows values from the heating system; the values are updated constantly
(see Fig. 31).
Resetting
Tap Reset (Fig. 30) to reset the control panel to factory settings.
After resetting, the system will be set as follows:
•
• Max. electricity - 1 kW
• Gas heating - On mode
• Target temperatures - 22.0 °C
• Hot water - In normal mode
Service page 1/2
Service page 2/2
Fig. 30, Settings
Fig. 31, Control Panel menus
To reset any error messages, disconnect the 12 V feed to the boiler.