EasyManuals Logo

Alfa Laval C MRPX 714HGV-74C User Manual

Alfa Laval C MRPX 714HGV-74C
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
43
5 Installation and first start 5.1 Before first start
5.2 Before first start
Pour about 13 litres lubricating oil of correct
grade into the worm gear housing – see
“Lubricants” in
Installation Manual
.
Check the oil (approx. half way up the sight
glass). Be aware of that a very small quantity
of oil may remain at the bottom edge of the
sight glass even when the gear housing is
emptied for oil.
Assemble the bowl and the inlet and outlet
parts as described in the
Service &
Maintenance Manual
.
Make sure that the frame hood bolts have
been tightened.
Make sure that the bolts for centring ring and
outlets have been tightened to the correct
torque. See Service &
Maintenance Manual
.
Make sure that the bolts for the inlet device
have been tightened.
Check that water and air are being supplied
to the control panel.
Make sure that cooling water is being supplied to
the separator.
Check at
(1) – from inlet device seal
(2) – from outlet upper seals (twin phase
separators only, see ill.)
(3) – from outlet bottom seal (at operation).
S0117811S0117911S0118021S0118111G0699221

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alfa Laval C MRPX 714HGV-74C and is the answer not in the manual?

Alfa Laval C MRPX 714HGV-74C Specifications

General IconGeneral
BrandAlfa Laval
ModelC MRPX 714HGV-74C
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals