14 The Electronic IF-171 Door Handle
Screw both key rosettes together through the door panel.
Attach the rosette covers and press them down firmly until you hear that they lock in place.
2.3 Initial Operation and Device Management
Initial Operation
Please proceed as follows for the initial operation:
In order to integrate the devices into your access control system, every device must read the data of your
facility card.
Hold the facility card in front of the reading unit. The status LED lights blue while the data is
transmitted. Hold your card in front of the reading unit until the green LED lights up.
Subsequently, you can parameterize the device (door initialization, setting the time). Specific
programming cards (e.g. door initialization card) or the software PegaSys Mobile are available for this
purpose.
If you are using LEGIC credentials the devices must additionally read the LEGIC-SAM card.
Management
Basically, there are two options for managing and parameterizing the devices:
Managing the devices in the access control system (e.g. IF-60x0). You can import the data from the
access control system by means of special programming cards or the software PegaSys Mobile.
Managing and parameterizing via the TeachIn app.
Detailed information on the aforementioned programs can be found in separate documentation.
See also
NetworkOnCard Mode of Operation ....................................................................................... 23
Outline of Parameterization of »NetworkOnCard« in Interflex Access Control Systems ....... 27
2.3.1 Perform Time Synchronization
Access authorizations may be time-dependent. Therefore, ensure correct and synchronous time settings
in the offline devices. Correct time settings are also important for subsequent analyses.
We therefore recommend synchronizing the built-in clock at least once a year.
Please use e. g. the software PegaSys Mobile or a time initialization card for this purpose.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allegion Interflex IF-171 and is the answer not in the manual?

Allegion Interflex IF-171 Specifications

General IconGeneral
BrandAllegion
ModelInterflex IF-171
CategoryDoor locks
LanguageEnglish

Related product manuals